Grabber reset

Last modified by Lev Andronov on 2025/04/30 11:32

Device reset is available for KAYA PCIe devices using Vision Point application or an API command.

Frame grabber reset using GUI

  1. Open Frame Grabber properties windo
  2. Expand "Device Control" category
  3. Click on the "Execute" command at the "Device reset" parameter

Frame grabber reset using API

This operation can be performed in the software using the following command:

KYFG_GrabberExecuteCommand(grabberHandle, "DeviceReset");

NOTE: Please note that after performing device reset a camera full rescan is required.


Frame grabber reset using KAYA Service control

  1. In the Tray click on the arrow to display hidden icons
  2. Find the KAYA Service control application
  3. Right-click on the KAYA Service control application icon and click on Reset of the required frame grabber

kaya_service_grabber_reset.png